A Trade Fire account gives you access to full trade pricing
1 items added to basket
Ceasefire Clean Agent Indirect Tube Based Fire Suppression System
Code: TF120-055-001
Safeguarding high-risk micro-environments from fire can be a significant challenge for your premises. This tube based suppression system is designed to provide the fire protection you need in those challenging spaces.
The Tube Based Suppression System (Fluoroketone Clean Agent) - Indirect System, is designed to swiftly tackle fires in high-risk enclosed spaces. For example, cabinets, servers, engines and wind turbines.
This is an indirect system, meaning that the extinguishing agent is discharged from a metal conduit across multiple high risk points. The agent is discharged after the heat sensitive tube breaks, which causes the pressure to drop and the metal conduit to tackle the fire.
This fire suppression system uses Fluoroketone Clean Agent. Fluoroketone leaves no residue behind, making it environmentally friendly and ideal for use on sensitive electronic equipment.
Residue-Free: Being a clean agent, it wont leave behind oily residue, particulate or corrosive material.
Classification: Works on class A, B, fires and fires involving electrically-charged devices.
Self- Actuated: Does not require any power supply and will function normally in the event of a power outage.
Electronics-Friendly: Shown to be electrically non-conductive and is safe for electrically charged equipment.
High-value Risk Protection: Suitable for protection on a range of high-value risks as it virtually eliminates damage to high-tech equipment, artwork and other delicate and sensitive objects.
No Clean-up Required After Discharge: After a discharge, the extinguishing agent can be removed by simple ventilation.
24-hour Protection: Automatic detection and actuation controls ensure fire protection is always on.
Flexible Design: Flexible tubing allows protection in areas that are difficult to access and may not be able to accommodate any other means of detection.
Tackles a fire from multiple points.
Close to the high risk areas, meaning fires are tackled quickly at the ignition source which reduces damage.
Product Code | Unit of Measure | CF-001355 | CF-001357 | CF-001359 | CF-0013561 |
Description | 2kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | 4kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | 6kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | 9kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | |
Capacity of Agent | KG | 2 (-5%) | 4 (-5%) | 6 (-5%) | 9 (-5%) |
Certification | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | |
Diameter of Shell | MM | 108 | 140 | 160 | 175 |
Total Height (approx.) | MM | 403 | 465 | 510 | 635 |
MOC of Shell | M.S. Sheet (CRCA ) | M.S. Sheet (CRCA ) | M.S. Sheet (CRCA ) | M.S. Sheet (CRCA ) | |
Mini. Wall Thickness | MM | 1.6 | 1.6 | 1.6 | 1.6 |
Test Pressure | BAR | 35 | 35 | 35 | 35 |
Anti-Corrosive Treatment | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | |
Service Pressure | BAR | 15 | 15 | 15 | 15 |
Type of Operating Mechanism | Automatic / Manual | Automatic / Manual | Automatic / Manual | Automatic / Manual | |
Type of Pressure Gauge | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | |
Type of Dis. pipe & Length | MM | Delivery pipe OD 10MM x 1MM Wall Thk. 5M | Delivery pipe OD 10MM x 1MM Wall Thk. 8 M | Delivery pipe OD 10MM x 1MM Wall Thk. 10M (Straight Line) 15 M (Ring Form) | Delivery pipe OD 10MM x 1MM Wall Thk. 12 M (Straight Line) 20 M (Ring Form) |
No of Max. nozzles | 2 | 4 | 6 | 8 | |
Type of valve | Indirect Low Pressure Valve (ILP) with Single outlet | Indirect Low Pressure Valve (ILP) with Single outlet | Indirect Low Pressure Valve (ILP) with Single outlet | Indirect Low Pressure Valve (ILP) with Single outlet | |
Operating Temperature Range | °C | -20 C to 60 C | -20 C to 60 C | -20 C to 60 C | -20 C to 60 C |
Applicable to Type of Fire | A, B, & Electrical Started Fire | A, B, & Electrical Started Fire | A, B, & Electrical Started Fire | A, B, & Electrical Started Fire | |
Product Warranty | YEAR | 1 | 1 | 1 | 1 |
Safeguarding high-risk micro-environments from fire can be a significant challenge for your premises. This tube based suppression system is designed to provide the fire protection you need in those challenging spaces.
The Tube Based Suppression System (Fluoroketone Clean Agent) - Indirect System, is designed to swiftly tackle fires in high-risk enclosed spaces. For example, cabinets, servers, engines and wind turbines.
This is an indirect system, meaning that the extinguishing agent is discharged from a metal conduit across multiple high risk points. The agent is discharged after the heat sensitive tube breaks, which causes the pressure to drop and the metal conduit to tackle the fire.
This fire suppression system uses Fluoroketone Clean Agent. Fluoroketone leaves no residue behind, making it environmentally friendly and ideal for use on sensitive electronic equipment.
Residue-Free: Being a clean agent, it wont leave behind oily residue, particulate or corrosive material.
Classification: Works on class A, B, fires and fires involving electrically-charged devices.
Self- Actuated: Does not require any power supply and will function normally in the event of a power outage.
Electronics-Friendly: Shown to be electrically non-conductive and is safe for electrically charged equipment.
High-value Risk Protection: Suitable for protection on a range of high-value risks as it virtually eliminates damage to high-tech equipment, artwork and other delicate and sensitive objects.
No Clean-up Required After Discharge: After a discharge, the extinguishing agent can be removed by simple ventilation.
24-hour Protection: Automatic detection and actuation controls ensure fire protection is always on.
Flexible Design: Flexible tubing allows protection in areas that are difficult to access and may not be able to accommodate any other means of detection.
Tackles a fire from multiple points.
Close to the high risk areas, meaning fires are tackled quickly at the ignition source which reduces damage.
Product Code | Unit of Measure | CF-001355 | CF-001357 | CF-001359 | CF-0013561 |
Description | 2kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | 4kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | 6kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | 9kg- FK 5-1-12 clean agent with (ILP) with integrated ball valve. | |
Capacity of Agent | KG | 2 (-5%) | 4 (-5%) | 6 (-5%) | 9 (-5%) |
Certification | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | |
Diameter of Shell | MM | 108 | 140 | 160 | 175 |
Total Height (approx.) | MM | 403 | 465 | 510 | 635 |
MOC of Shell | M.S. Sheet (CRCA ) | M.S. Sheet (CRCA ) | M.S. Sheet (CRCA ) | M.S. Sheet (CRCA ) | |
Mini. Wall Thickness | MM | 1.6 | 1.6 | 1.6 | 1.6 |
Test Pressure | BAR | 35 | 35 | 35 | 35 |
Anti-Corrosive Treatment | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | Outer surfaces are EP Powder coated having Dry Film Thickness 50 Micron (Min.) RAL Shade 3000 | |
Service Pressure | BAR | 15 | 15 | 15 | 15 |
Type of Operating Mechanism | Automatic / Manual | Automatic / Manual | Automatic / Manual | Automatic / Manual | |
Type of Pressure Gauge | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | |
Type of Dis. pipe & Length | MM | Delivery pipe OD 10MM x 1MM Wall Thk. 5M | Delivery pipe OD 10MM x 1MM Wall Thk. 8 M | Delivery pipe OD 10MM x 1MM Wall Thk. 10M (Straight Line) 15 M (Ring Form) | Delivery pipe OD 10MM x 1MM Wall Thk. 12 M (Straight Line) 20 M (Ring Form) |
No of Max. nozzles | 2 | 4 | 6 | 8 | |
Type of valve | Indirect Low Pressure Valve (ILP) with Single outlet | Indirect Low Pressure Valve (ILP) with Single outlet | Indirect Low Pressure Valve (ILP) with Single outlet | Indirect Low Pressure Valve (ILP) with Single outlet | |
Operating Temperature Range | °C | -20 C to 60 C | -20 C to 60 C | -20 C to 60 C | -20 C to 60 C |
Applicable to Type of Fire | A, B, & Electrical Started Fire | A, B, & Electrical Started Fire | A, B, & Electrical Started Fire | A, B, & Electrical Started Fire | |
Product Warranty | YEAR | 1 | 1 | 1 | 1 |
At Trade Fire, we supply a wide range of fire safety products, including various types of fire extinguishers such as water and CO₂ models.
Alongside our extinguisher range, we offer fire blankets, extinguisher stands, smoke and fire alarms, first aid kits, and other essential fire safety equipment, all from trusted brand manufacturers at competitive prices.
Every product comes with a full warranty and includes fixings where required. For reliable extinguishers, alarms, and complete fire safety solutions, choose Trade Fire for quality, expertise and excellent service.
We use cookies to enhance your site experience. Choose your preferences below.