Safeguarding high-risk micro-environments from fire can be a significant challenge for your premises. This tube based suppression system is designed to provide the fire protection you need in those challenging spaces.
The Tube Based Suppression System (Foam) - Indirect System, is designed to swiftly tackle fires in high-risk enclosed spaces. For example, cabinets, generators, engines and wind turbines.
This is an indirect system, meaning that the extinguishing agent is discharged from a metal conduit across multiple high risk points. The agent is discharged after the heat sensitive tube breaks, which causes the pressure to drop and the metal conduit to tackle the fire.
This fire suppression system uses foam. Foam is highly effective and a fantastic choice for swiftly tackling fires in industrial areas.
Classification: Works on class A, B fires and those involving flammable liquids. Effective on a wide range of flammable and combustible liquids such as oil and petrol.
Self- Actuated: Does not require any power supply and will function normally in the event of a power outage.
24-hour Protection: Automatic detection and actuation controls ensure fire protection is always ‘on’.
Flexible Design: Flexible tubing allows protection in areas that are difficult to access and may not be able to accommodate any other means of detection.
International Quality Standards: Manufactured to the highest global and national standards like BSI, ISI and CE. The system is also BSI tested for Forced and Natural Air Flow cabinet applications.
Rugged Design: Can withstand even harsh conditions where other types of detection systems might be rendered inadequate.
Product Code | Unit of Measure | CF-001507 | CF-001508 | CF-001385 | CF-001386 |
Description | 2L FFF ILP system | 3L FFF ILP system | 6L FFF ILP system | 9L FFF ILP system | |
Capacity of Agent | KG | 2 | 3 | 6 | 9 |
Certification | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | |
Diameter of Shell | MM | 108 | 140 | 160 | 175 |
Total Height (approx.) | MM | 403 | 465 | 510 | 635 |
MOC of Shell | M.S. Sheet (CRCA grade 2) | M.S. Sheet (CRCA grade 2) | M.S. Sheet (CRCA grade 2) | M.S. Sheet (CRCA grade 2) | |
Mini. Wall Thickness | MM | 1.6 | 1.6 | 1.6 | 2.0 |
Test Pressure | BAR | 35 | 35 | 35 | 35 |
Anti-Corrosive Treatment | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | |
Service Pressure | BAR | 15 | 15 | 15 | 15 |
Type of Operating Mechanism | Automatic / Manual | Automatic / Manual | Automatic / Manual | Automatic / Manual | |
Type of Pressure Gauge | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | |
Type of Dis. pipe & Length | MM | Delivery pipe OD 10MM x 1MM Wall Thk. 4 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 6 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 8 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 12 M Besides Nozzle Network |
No of Max. nozzles | 2 | 4 | 6 | 8 | |
Type of valve | Indirect Low Pressure Valve (ILP) with two outlet | Indirect Low Pressure Valve (ILP) with two outlet | Indirect Low Pressure Valve (ILP) with two outlet | Indirect Low Pressure Valve (ILP) with two outlet | |
Operating Temperature Range | °C | 5°C to 60°C | 5°C to 60°C | 5°C to 60°C | 5°C to 60°C |
Applicable to Type of Fire | A, B Class Fire | A, B Class Fire | A, B Class Fire | A, B Class Fire | |
Product Warranty | YEAR | 1 | 1 | 1 | 1 |
Safeguarding high-risk micro-environments from fire can be a significant challenge for your premises. This tube based suppression system is designed to provide the fire protection you need in those challenging spaces.
The Tube Based Suppression System (Foam) - Indirect System, is designed to swiftly tackle fires in high-risk enclosed spaces. For example, cabinets, generators, engines and wind turbines.
This is an indirect system, meaning that the extinguishing agent is discharged from a metal conduit across multiple high risk points. The agent is discharged after the heat sensitive tube breaks, which causes the pressure to drop and the metal conduit to tackle the fire.
This fire suppression system uses foam. Foam is highly effective and a fantastic choice for swiftly tackling fires in industrial areas.
Classification: Works on class A, B fires and those involving flammable liquids. Effective on a wide range of flammable and combustible liquids such as oil and petrol.
Self- Actuated: Does not require any power supply and will function normally in the event of a power outage.
24-hour Protection: Automatic detection and actuation controls ensure fire protection is always ‘on’.
Flexible Design: Flexible tubing allows protection in areas that are difficult to access and may not be able to accommodate any other means of detection.
International Quality Standards: Manufactured to the highest global and national standards like BSI, ISI and CE. The system is also BSI tested for Forced and Natural Air Flow cabinet applications.
Rugged Design: Can withstand even harsh conditions where other types of detection systems might be rendered inadequate.
Product Code | Unit of Measure | CF-001507 | CF-001508 | CF-001385 | CF-001386 |
Description | 2L FFF ILP system | 3L FFF ILP system | 6L FFF ILP system | 9L FFF ILP system | |
Capacity of Agent | KG | 2 | 3 | 6 | 9 |
Certification | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | |
Diameter of Shell | MM | 108 | 140 | 160 | 175 |
Total Height (approx.) | MM | 403 | 465 | 510 | 635 |
MOC of Shell | M.S. Sheet (CRCA grade 2) | M.S. Sheet (CRCA grade 2) | M.S. Sheet (CRCA grade 2) | M.S. Sheet (CRCA grade 2) | |
Mini. Wall Thickness | MM | 1.6 | 1.6 | 1.6 | 2.0 |
Test Pressure | BAR | 35 | 35 | 35 | 35 |
Anti-Corrosive Treatment | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | |
Service Pressure | BAR | 15 | 15 | 15 | 15 |
Type of Operating Mechanism | Automatic / Manual | Automatic / Manual | Automatic / Manual | Automatic / Manual | |
Type of Pressure Gauge | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | |
Type of Dis. pipe & Length | MM | Delivery pipe OD 10MM x 1MM Wall Thk. 4 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 6 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 8 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 12 M Besides Nozzle Network |
No of Max. nozzles | 2 | 4 | 6 | 8 | |
Type of valve | Indirect Low Pressure Valve (ILP) with two outlet | Indirect Low Pressure Valve (ILP) with two outlet | Indirect Low Pressure Valve (ILP) with two outlet | Indirect Low Pressure Valve (ILP) with two outlet | |
Operating Temperature Range | °C | 5°C to 60°C | 5°C to 60°C | 5°C to 60°C | 5°C to 60°C |
Applicable to Type of Fire | A, B Class Fire | A, B Class Fire | A, B Class Fire | A, B Class Fire | |
Product Warranty | YEAR | 1 | 1 | 1 | 1 |
At Trade Fire, we supply a wide range of fire safety products, including various types of fire extinguishers such as water and CO₂ models.
Alongside our extinguisher range, we offer fire blankets, extinguisher stands, smoke and fire alarms, first aid kits, and other essential fire safety equipment, all from trusted brand manufacturers at competitive prices.
Every product comes with a full warranty and includes fixings where required. For reliable extinguishers, alarms, and complete fire safety solutions, choose Trade Fire for quality, expertise and excellent service.
We use cookies to enhance your site experience. Choose your preferences below.