Kentec Sigma Bi-wire Apollo AlarmSense Fire Alarm Panel | 2, 4 or 8 Zone
Code: TF401-140
The Kentec Sigma AlarmSense panels, available in 4-zone (KA11040M2) and 8-zone (KA11080M2) versions, as well as the 2-zone (KA11020M2) model, form part of an AlarmSense system that enables all detection and sounder devices in a given zone to be wired to the same pair of cables. This significantly reduces cabling and installation requirements, cutting costs without compromising performance.
Apollo AlarmSense compatible
Available in 2, 4, and 8 detection zone models - select above
Integral, mains-powered battery charger and power supply
Fully programmable using simple menu options
Conventional sounder circuits included
Incorporating a "Selectable Local Alarm" feature, these panels are particularly useful in Houses of Multiple Occupation (HMOs) such as student accommodations and nursing homes. When sounder or sounder beacon bases are set to local alarm mode, an alarm will initially trigger only the sounder connected to the activated detector. This feature allows occupants time to clear minor false alarms (e.g., burnt toast) before a full evacuation is required. If the detector reactivates after being reset, a general alarm will sound throughout the premises. Activation of a second detector or a call point will immediately trigger the general alarm.
Designed for flexibility and ease of installation, the Sigma AlarmSense is compatible with all Apollo AlarmSense Detectors and Sounders ensuring full compliance with safety regulations while streamlining fire alarm system setup.
Apollo AlarmSense compatible
Available in 2, 4, and 8 detection zone models (KA11020M2, KA11040M2, KA11080M2)
Integral, mains-powered battery charger and power supply
Fully programmable using simple menu options
Adjustable sounder delay time
Sounder configuration options
Conventional sounder circuits included
Zonal sounder delay – detectors only
Zonal sounder delay – call points only
Coincidence input selection
I.S. Barrier selection by zone
Short circuit fire detection by zone
Non-latching zones
Silent zones
Zone input delay
Easy-to-set general panel configuration
Specification | Details |
|---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour | - Lid & box: BS 00 A 05 grey - fine texture <br> - Control panel & labels: RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Common Sounder Output Rating | 0.5A per output (max 1.6A over all outputs) |
AlarmSense Sounder Output Rating | 0.2A per output |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 3K3 5% |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
The Kentec Sigma AlarmSense panels, available in 4-zone (KA11040M2) and 8-zone (KA11080M2) versions, as well as the 2-zone (KA11020M2) model, form part of an AlarmSense system that enables all detection and sounder devices in a given zone to be wired to the same pair of cables. This significantly reduces cabling and installation requirements, cutting costs without compromising performance.
Apollo AlarmSense compatible
Available in 2, 4, and 8 detection zone models - select above
Integral, mains-powered battery charger and power supply
Fully programmable using simple menu options
Conventional sounder circuits included
Incorporating a "Selectable Local Alarm" feature, these panels are particularly useful in Houses of Multiple Occupation (HMOs) such as student accommodations and nursing homes. When sounder or sounder beacon bases are set to local alarm mode, an alarm will initially trigger only the sounder connected to the activated detector. This feature allows occupants time to clear minor false alarms (e.g., burnt toast) before a full evacuation is required. If the detector reactivates after being reset, a general alarm will sound throughout the premises. Activation of a second detector or a call point will immediately trigger the general alarm.
Designed for flexibility and ease of installation, the Sigma AlarmSense is compatible with all Apollo AlarmSense Detectors and Sounders ensuring full compliance with safety regulations while streamlining fire alarm system setup.
Apollo AlarmSense compatible
Available in 2, 4, and 8 detection zone models (KA11020M2, KA11040M2, KA11080M2)
Integral, mains-powered battery charger and power supply
Fully programmable using simple menu options
Adjustable sounder delay time
Sounder configuration options
Conventional sounder circuits included
Zonal sounder delay – detectors only
Zonal sounder delay – call points only
Coincidence input selection
I.S. Barrier selection by zone
Short circuit fire detection by zone
Non-latching zones
Silent zones
Zone input delay
Easy-to-set general panel configuration
Specification | Details |
|---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour | - Lid & box: BS 00 A 05 grey - fine texture <br> - Control panel & labels: RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Common Sounder Output Rating | 0.5A per output (max 1.6A over all outputs) |
AlarmSense Sounder Output Rating | 0.2A per output |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 3K3 5% |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
TF402-133
TF402-134
TF402-135
TF402-142
TF402-143
At Trade Fire, we supply a wide range of fire safety products, including various types of fire extinguishers such as water and CO₂ models.
Alongside our extinguisher range, we offer fire blankets, extinguisher stands, smoke and fire alarms, first aid kits, and other essential fire safety equipment, all from trusted brand manufacturers at competitive prices.
Every product comes with a full warranty and includes fixings where required. For reliable extinguishers, alarms, and complete fire safety solutions, choose Trade Fire for quality, expertise and excellent service.
We use cookies to enhance your site experience. Choose your preferences below.